IONICS HV Power Supply for Capacitor Testing

1kV to 100kV, 2.2kW to 6kW

TECHNICAL SPECIFICATIONS

PARAMETER SPECIFICATION
Input Voltage 415V ±10% AC, 50Hz, three phase
Output Current Range* 1kV to 100kV DC
Output Power Range* 2kW to 6kW
Polarity* Positive
Voltage Regulation Line
Load
≤ 0.1% for ±10% variation in input voltage
≤ 0.5% for 0 to 100% load variation
Current Regulation Line
Load
≤ 0.1% for ±10% variation in input voltage
≤ 0.5% for 0 to 100% load variation
Stability < 0.1%/hour after 1 hour warm up
Temperature Coefficient < 0.1% / °C
Regulating Mode Constant current - Constant voltage
Cooling Forced air cooling
Voltage & Current Control # Local: By 10-turn potentiometers on the front panel
Remote: 0 to 10V DC signals for voltage & current control; OR Control through computer interface
Protections* Against over load and short circuit
Remote Controls & Signals through Pluggable Connector / D-Connector (External RS232 Microcontroller Module) # 10V DC reference
10V DC HV enable signal
0 to 10V DC signal for voltage & current control
0 to 10V DC signal for voltage & current monitoring
Front Panel Power ON/OFF MCB with indication
HV ON/OFF switch with indication
3½ digit current and voltage meters
10-turn potentiometers for current and voltage control
Constant current – constant voltage mode indication
Charging complete indication
Back Panel Terminal block for 3 phase input
Fuse holders with fuses
Terminal for HV output with 10ft of detachable high voltage cable
Stud for grounding the unit
Remote interface connector #
Topology High frequency resonant / PWM-controlled switch mode
Switching Device IGBT
Cabinet 19” rack, powder coated

# For remote operation RS232 available at an extra cost

Remote Interface Connector Configuration

Pins 14 Pin Pluggable Connector (Analog Interface) 25 Pin D Connector (Digital Interface)
1 Earth Earth
2 Common Common
3 Interlock HV Enable
4 HV Enable Voltage Control Remote
5 Reference Current Control Remote
6 Common Over Voltage Control Remote*
7 Voltage Control Remote Over Current Control Remote*
8 Voltage Control Local Common
9 Common Voltage Monitor
10 Current Control Remote Current Monitor
11 Current Control Local Reserved Monitor*
12 Common Reserved Monitor*
13 Voltage Monitor Common
14 Current Monitor Mode Status
15 Interlock Status
16 HV ON Status
17 Common
18 PS Fault Status*
19 Over Voltage Status*
20 Over Current Status*
21 Over Temperature Status*
22 Open Circuit Status*
23 Phase Failure Status*
24 Reserved Status*
25 Common

*Optional. To be specified by the user only as per application’s requirement.

Ordering Code
HV 040 K 600 W N C U D 5 T

Ordering Code
HV 040 K
1
600 W N
2 3
C U D 5 T
5 6
Section Description Options Options Description
1 Output Voltage XXX Value of output voltage
2 Output Power YYY Value of output power
3 Polarity
P
N
Positive
Negative
4 Short Circuit
A
B
C

D
Shut down
Shut down & manual reset
Shut down & automatic restart
Constant current
5 Regulation Mode
4
5

Constant voltage
Constant voltage & constant current
6 Control Mode
L
R

T

Local control
Remote control through D-connector
Remote control through pluggable connector