REGULATED REVERSIBLE HIGH VOLTAGE POWER SUPPLY

1kV to 150kV, 50W to 30kW

TECHNICAL SPECIFICATIONS

PARAMETER SPECIFICATION
Input Voltage 230V ±10% A C, 50Hz, single phase / 415V ±10% AC, 50Hz, three phase
Output Voltage Range* 1kV DC to 150kV DC
Output Power Range* 50W to 30kW
Number of outputs 1
Polarity* Reversible Positive or Negative selection is by a switch on front panel upto 50kV models and simply reversing multiplier / rectifier stack above 50kV
Line Regulation Upto 0.05% for ±10% variation in input voltage
Load Regulation Upto 0.05% for 0 to 100% load variation
Ripple Upto 0.1% rms
Stability <0.01%/hour after 1 hour warm up
Regulation Mode* Constant voltage – Constant current
Voltage & Current Control* By 10-turn potentiometers on the front panel
Protections* Against over load, short-circuit and arc
Front Panel Power ON/OFF switch / MCB with indication
HV ON/OFF switch with indication
Polarity indication
3½ dig it voltage and current meters
10-turn potentiometers for voltage and current control
Constant voltage – constant current mode indication
Back Panel Socket for mains input with 250V, 10A/20A 3 conductor power cord of 1.5 meters / Terminal block for 3 phase input
Fuse holder with fuse
Terminal for HV output with 10ft of detachable high voltage cable Stud for grounding the unit
Topology High frequency resonant / PWM-controlled switch mode
Switching Device IGBT
Cabinet
1kV to 30kV
35kV to 150kV
19” rack, powder coated, 3U to 8U depending on power rating
19” rack, powder coated, 3U to 8U depending on power rating followed by a separate multiplier cabinet

*Optional. To be specified by the user.

Remote Interface Connector Configuration

Pins 28 Pin Pluggable Connector 25 Pin D Connector
1 Earth Earth
2 Common Common
3 Interlock HV Enable
4 HV Enable Voltage Control Remote
5 Reference Current Control Remote
6 Common Over Voltage Control Remote*
7 Voltage Control Remote Over Current Control Remote*
8 Voltage Control Local Common
9 Common Voltage Monitor
10 Current Control Remote Current Monitor
11 Current Control Local Reserved Monitor*
12 Common Reserved Monitor*
13 Voltage Monitor Common
14 Current Monitor Mode Status
15 Common* Interlock Status
16 Voltage Mode Status* HV ON Status
17 Current Mode Status* Common
18 HV ON Status* PS Fault Status*
19 Common* Over Voltage Status*
20 PS Fault Status* Over Current Status*
21 Over Voltage Status* Over Temperature Status*
22 Over Current Status* Open Circuit Status*
23 Over Temperature Status* Phase Failure Status*
24 Open Circuit Status* Reserved Status*
25 Phase Failure Status* Common
26 Common*
27 Over Voltage Control*
28 Over Current Control*

*Optional. To be specified by the user only as per application’s requirement.

Ordering Code
HV 200 K 010 K N C J A 5 R

Ordering Code
HV 200 K
1 2 3
010 K N
4 5 6
C J A 5 R
7 8 9 10 11
Section Description Options Options Description
1 Type of Power supply
HV
HC
MR

ML

MF

High Voltage
High Current
Miniature Module with Remote Control
Miniature Module with Local Control
Miniature Module with Front Panel Control
2 Output Voltage XXX Value of output Voltage
3 Output Voltage Range
V
K
Volt
Kilo Volt
4 Output Power YYY Value of output Power
5 Output power Range
W
K
Watt
Kilo Volt
6 Polarity
P
PN
PD
PB
PR
Positive
Negative
Dual
Bipolar
Reversible
7 Mode
P
C
F
S
Q
Pulsed
Continuous
Fixed
Sine
Square
8 Input Voltage
1
2
3
I
J
U
12V DC
24V DC
72V DC
230V DC
415V AC
115/230V AC
9 Short Circuit
A
B
C

D
Shut Down
Shut Down & Manual Reset
Shut Down & Automatic Restart
Constant Current
10 Operation Mode
4

5

Constant Voltage / Constant current (HV/HC)
Constant Voltage & Constant current
11 Control
L
R

T

S

Local Control
Remote control through D-Connector (RS-232)
Remote control through Pluggable Connector
Remote control through Terminal Block