Glow Discharge
REGULATED HIGH VOLTAGE POWER SUPPLY
-6kV, 1A
This series of power supplies can generate output that ranges from 3kV to 6kV, 3kW to 6kWand are housed in compact 19” racks to give a highly regulated output. These unit are typically used for glow discharge application.
TECHNICAL SPECIFICATIONS
PARAMETER | SPECIFICATION |
---|---|
Input Voltage | 415V±10% AC, 50Hz, three phase |
Output Voltage | 0 to 6kV DC |
Output Current | 0 to 1A |
Polarity* | Negative |
Voltage Regulation | Line regulation: ≤0.05% of full voltage and +500mv over the specified input range. Load regulation: ≤0.1% of full voltage and +500mv for no load to full load change. |
Current Regulation | Line regulation: ≤ 0.1% of full current over the specified input range. Load regulation: ≤0.2% of full current and +/- 100uA for any voltage change. |
Stability | ≤ 0.05%/hour after 1 hour warm up |
Temperature Coefficient | < 0.05%/ºC |
Regulating Mode | Constant voltage – constant current |
Voltage & Current Control | Local: By 10-turn potentiometers with lockable counting dials on the front panel over entire range from zero to maximum rating Remote: Control through computer interface* |
Protections* | Against over current, over voltage, over temperature, short-circuit and arc |
Remote Controls & Signals through D-Connector (External RS232 Microcontroller Module) * | 10V DC reference 10V DC HV enable signal 0 to 10V DC signal for voltage & current control 0 to 10V DC signal for voltage & current monitoring |
Cooling | Forced air |
Front Panel | MCB for mains power ON/OFF with indication 3½ digit voltage and current meters 10-turn potentiometers for voltage and current control LED indication for faulty trip Push button to reset trip condition Constant voltage – constant current mode indication |
Back Panel | Terminal block for mains input Fuse holders with fuse Terminals for output Stud for grounding the unit |
Topology | High frequency resonant / PWM-controlled switch mode |
Switching Device | IGBT |
Cabinet | 19” rack, powder coated |
*Optional. To be specified by the user.
*Optional. RS232 interface available at an extra cost.
Pins | 14 Pin Pluggable Connector (Analog Interface) | 25 Pin D Connector (PC Interface) |
---|---|---|
1 | Earth | Earth |
2 | Common | Common |
3 | Interlock | HV Enable |
4 | HV Enable | Voltage Control Remote |
5 | Reference | Current Control Remote |
6 | Common | Over Voltage Control Remote* |
7 | Voltage Control Remote | Over Current Control Remote* |
8 | Voltage Control Local | Common |
9 | Common | Voltage Monitor |
10 | Current Control Remote | Current Monitor |
11 | Current Control Local | Reserved Monitor* |
12 | Common | Reserved Monitor* |
13 | Voltage Monitor | Common |
14 | Current Monitor | Mode Status |
15 | Interlock Status | |
16 | HV ON Status | |
17 | Common | |
18 | PS Fault Status* | |
19 | Over Voltage Status* | |
20 | Over Current Status* | |
21 | Over Temperature Status* | |
22 | Open Circuit Status* | |
23 | Phase Failure Status* | |
24 | Reserved Status* | |
25 | Common |