PARAMETER |
SPECIFICATION |
Input Voltage |
230V ±10% AC, 50Hz, single phase |
Output Voltage Range* |
1kV DC to 50kV DC |
Output Power Range* |
50W to 300W |
Number of Outputs |
1 |
Polarity* |
Bipolar. Negative to positive or vice versa , automatically variable through zero by a potentiometer |
Line Regulation |
≤ 0.1% for ± 10% variation in input voltage |
Load Regulation |
≤ 0.1% for 0 to 100% load variation |
Ripple |
≤0.1% rms at full rating |
Stability |
< 0.1%/hour after 1 hour warm up |
Regulation Mode* |
Constant voltage |
Voltage Control* |
By 10-turn potentiometers on the front panel |
Protections* |
Against over load, short-circuit and arc During faults, power supply trips and to be reset manually |
Front Panel |
Power ON/OFF switch with indication
HV ON/OFF switch with indication
3½ digit voltage and current meters
10-turn potentiometers for voltage and control
Polarity indication
LED indication for trip
Push button to restart the power supply in case of trip |
Back Panel |
Socket for mains input with 250V, 10A 3 conductor power cord of 1.5 meters
Fuse holder with fuse
Terminal for HV output with 10ft of detachable high voltage cable Stud for grounding the unit |
Topology |
High frequency resonant / PWM-controlled switch mode |
Switching Device |
IGBT |
Cabinet |
3U 19” rack, powder coated |