PARAMETER |
SPECIFICATION |
Input Voltage |
230V ±10% AC, 50Hz, single phase for output power ≤2kW
415V ±10% AC, 50Hz, three phase for output power ≥2kW |
Output Voltage Range* |
1kV to 100kV DC |
Output Power Range* |
50W to 5kW |
Number of Outputs |
2 |
Polarity* |
Positive & negative (Two outputs will be available simultaneously) |
Voltage Regulation |
Line |
|
Load |
|
≤ 0.1 to 0.05% for ±10% variation in input voltage |
≤ 0.5 to 0.1% for 0 to 100% load variation |
|
Current Regulation |
Line |
|
Load |
|
≤ 0.5 to 0.1% for ±10% variation in input voltage |
≤ 0.5 to 0.1% for 0 to 100% load variation |
|
Load Regulation |
≤ 0.1% for 0 to 100% load variation |
Stability |
< 0.1 to 0.05%/hour after 1 hour warm up |
Temperature Coefficient |
< 0.1 to 0.05%/ºC |
Regulating Mode |
Constant voltage – Constant current |
Voltage & Current Control # |
Voltage & Current Control # Local: By 10-turn potentiometers on the front panel
Remote: 0 to 10V DC signals for voltage & current control; OR
Control through computer interface |
Protections* |
Against short-circuit and arc |
Remote Controls & Signals through Pluggable Connector / D-Connector (External RS232 Microcontroller Module) # |
10V DC reference
10V DC HV enable signal
0 to 10V DC signal for voltage & current control
0 to 10V DC signal for voltage & current monitoring |
Front Panel |
Power ON/OFF switch with indication
Output ON/OFF switch with indication (2 sets)
3½ digit voltage and current meters (2 sets)
10-turn potentiometer for voltage control
Constant voltage – constant current mode indication (2 sets) |
Back Panel |
Socket for mains input with 250V, 10A 3 conductor power cord of 1.5 meters / Terminal block for 3 phase input
Fuse holder with fuse
Terminals for output
Stud for grounding the unit
Remote interface connector # (2 sets) |
Topology |
High frequency resonant / PWM-controlled switch mode |
Switching Device |
IGBT |
Cabinet |
19” rack, powder coated |