PARAMETER |
SPECIFICATION |
Input Voltage |
230V ±10% A C, 50Hz, single phase |
Output Voltage Range* |
1kV DC to 150kV DC |
Output Power Range* |
50W to 1kW |
Polarity* |
Positive |
Line Regulation |
≤0.5% for 10% variation in input voltage |
Load Regulation |
≤0.1% for 0 to 100% load variation |
Ripple |
≤0.1% rms at full rating |
Stability |
Better than 0.05%/hour after 1 hour warm up |
Regulation Mode* |
Constant voltage – Constant current |
Voltage & Current Control* |
Local: By 10-turn potentiometers on the front panel
Remote: 0 to 10V DC signals for voltage & current control; OR
Control through computer interface. |
Protections* |
Against over load, over current, over voltage, short-circuit and arc |
Remote Controls & Signals through Pluggable Connector / D-Connector (External RS232 Microcontroller Module) * |
10V DC reference
10V DC HV enable signal
0 to 10V DC signal for voltage & current control
0 to 10V DC signal for voltage & current monitoring |
Front Panel |
AC power ON/OFF switch with indication
HV ON/OFF switch with indication
3½ digit voltage and current meters
10-turn potentiometers for voltage and current control
Constant voltage – constant current mode indication |
Back Panel |
Socket for mains input with 250V, 10A 3 conductor power cord of 1.5 meters
Fuse holder(s) with fuse
Terminal for HV output with 10ft of detachable high voltage cable Stud for grounding the unit
Remote interface connector* |
Topology |
High frequency resonant / PWM-controlled switch mode |
Switching Device |
IGBT |
Cabinet |
2U/3U, 19” rack, powder coated |