PARAMETER |
SPECIFICATION |
Input Voltage |
230V ±10% AC, 50Hz, single phase |
Output Voltage Range* |
Upto 20kV peak to peak |
Output Power |
Upto 1kW peak to peak |
Output Waveform |
AC Square wave |
Line Regulation |
±1% for ±10% variation in input voltage |
Frequency Range |
10kHz to 50kHz |
Regulating Mode |
Constant voltage |
Voltage & Frequency Control |
By 10-turn potentiometers on the front panel |
Protections |
Against over load, short-circuit and arc
During short circuit, power supply trips & to be reset manually |
Front Panel |
Power ON/OFF switch with indication
HV ON/OFF switch with indication
3½ digit voltage, frequency and current meters
10-turn potentiometers for voltage and frequency control
LED indication for fault trip
Push button for trip reset |
Back Panel |
Socket for mains input with 250V, 10A 3 conductor power cord of 1.5 meters Fuse holder with fuse
Terminal for HV output with 10ft of detachable high voltage cable
Stud for grounding the unit |
Cabinet |
19” rack |