PARAMETER |
SPECIFICATION |
Input Voltage |
230V ±10% AC, 50Hz, single phase for output power ≤ 2kW
415V ±10% AC, 50Hz, three phase for output power > 2kW |
Output Voltage Range* |
+40 to -800V DC in pulsed mode (variable)
0 to -800V DC in continuous mode (variable) |
Output Power Range* |
50W to 5kW |
Frequency Range* |
1kHz to 100kHz |
Frequency Control Range |
Minimum to maximum of rated frequency range |
Duty Cycle Control Range in Pulsed Mode* |
10% to 45% variable (A 10V signal is provided at the back panel for measurement with an external oscilloscope) |
Mode of Operation |
Pulsed or continuous |
Regulating Mode |
Constant voltage – Constant current |
Voltage, Current, Frequency & Duty Cycle Control |
By 10-turn potentiometers on the front panel |
Protections* |
Against over load, short-circuit and arc |
Front Panel |
Power ON/OFF switch / MCB with indication
3½ digit voltage, current and frequency meters
10-turn potentiometers for voltage, current, frequency and duty cycle control selector switch for pulse mode or continuous mode selection
Constant voltage – constant current mode indication
Pulse mode- continuous mode indication |
Back Panel |
Socket for mains input with 250V, 10A 3 conductor power cord of 1.5 meters / Terminal blocks for 3 phase input
Fuse holder with fuse
BNC connector to measure duty ratio with an external oscilloscope
Terminal for HV output with 10ft of detachable high voltage cable Stud for grounding the unit |
Topology |
High frequency resonant / PWM-controlled switch mode |
Switching Device |
IGBT |
Cabinet |
19” rack, powder coated, 3U to 5U depending on power rating |